Clinker temperature at cooler end

Clinker temperature at cooler end

Pyrometer at cooler gives the temperature output which ensure uniformity at conveyor and also gives alarms to operator if there is any Hot clinker left by cooler at discharge end

Compact sensor with environmental rating IP65

  • Optimized optics for covering broad conveyors

  • Simple two-wire installation (three wires with alarm output)

  • Adjustable temperature range and alarm setpoint via HART/RS232 communication

  • Special part numbers: DZA

General and Electrical Specifications

Environmental rating: IP65 (IEC529) Material: V4A, DIN1.4571 (DZA special)

Ambient temperature:

  • 70 degree Celsius (without cooling)

  • 120 degree Celsius (with air cooling)

  • 175 degree Celsius (with water cooling)

Air flow: 28 l / min at 1 bar

Relative humidity: 10 – 95 per cent, non-condensing Shock: IEC 68-2-27, 50 G, 11 ms, 3 axis Vibration: IEC 68-2-27, 3 G, 3 axis, 11 – 200 Hz Weight: 1,5 kg

Electrical specifications: Analog output 4 to 20 mA alarm output 24 V / 150 mA

Power supply: 24 VDC ±10 per cent

Communication by the management of the company

No stories found.
Indian Cement Review
www.indiancementreview.com